LSOH(Low Smoke Zero Halogen) CABLE
LSOH(Low Smoke Zero Halogen) CABLE
MOQ : piece
Lead Time : Days
Seller Support : Trade Authenticity Guaranteed & Accepting
Payment : L/C,T/T
Product details
Supply Ability
- Warranty(Year):1 Year
Product Specifications
Product Description
Halogen-freecables WDZBYJV
LSOH(Low Smoke Zero Halogen) CABLE
Salesjycable[at]hotmail[dot]com
Jacket material | PVC | Wire maximum diameter, | 500 mm |
insulating material, | Plastic insulated power cable | Core material, | red copper wire |
voltage classes, | Low and medium voltage power cables 35kv and below | nominal cross section, | 1-630 mm2 |
type | WDZBYJV | ||
insulation thickness | 50 mm | ||
cores | 1-20 |
properties
1,oducts according toGB/T12706-2002 national standard
2, Partial dischargetest: rated voltage Uo for and kv and below cable put power "and PC; Ratedvoltage Uo for more than eighteen kv power cable put < 5 PC.
3, 20ohm conductor dcresistivity: copper core acuities were 0.017241 OHM best callus induction/moaluminium acuities were 0.028 OHM best callus induction/m.
4, combustionperformance(flame retardant cable) according to GB/T18380-2001 standard test
Operatingcharacteristic
1、Cablehighest long-term working temperature is 90 ohm
2、Cable the ambient temperature under installation shouldnot below 0 ohm, cable bending radius should be more than twenty times of cablediameter.
3、In case of short circuit, the highest temperature ofthe conductor shall not be more than 250 ohm, duration is no more than 5seconds
4、Laying temperature shall not be lower than 0 ohm。
5、Short circuit, the highest temperature of the conductorshall not be more than 160 ohm, duration is no more than 5 seconds。
6、Cable used in rated voltage 0.6/1、1.8/3、3.6/6、6/6、6/10、8.7/10、8.7/15、12/20、21/35、26/35KVPower transmission and distribution system。
7、YJV YJLV suitable for indoor and outdoor installation,can withstand certain laying traction, but unable to bear external mechanicalforces of situations. Single core cable are not allowed in the pipe laying inferromagnetic materials. YJV22, YJLV22 suitable for buried laying, able to bearexternal mechanical forces effect, but unable to bear large pulling force.
Production Range,
Type | Cores | Rated voltage KV | |||||
0.6/1 | 1.8/3 | 3.6/6,6/6 | 6/10,8.7/10 | 8.7/15~12/20 | 18/20~26/35 | ||
Conductive wire core nominal section MM2 | |||||||
YJV | 1 | 1.5~800 | 10~800 | 25~1200 | 25~1200 | 35~1200 | 50~1200 |
3 | 1.5~300 | 10~300 | 25~300 | 25~300 | 35~300 | - | |
4 | 4~240 | - | - | - | - | - | |
YJV | 1 | 2.5~1000 | 10~1000 | 25~1200 | 25~1200 | 35~1200 | 50~1200 |
3 | 2.5~300 | 10~300 | 20~300 | 25~300 | 35~300 | - | |
4 | - | - | - | - | - | - | |
YJV22 | - | - | - | - | - | - | - |
3 | 4~300 | 4~300 | 25~300 | 25~300 | 35~300 | - | |
4 | 4~240 | 4~240 | - | - | - | - | |
YJV23 | - | - | - | - | - | - | - |
3 | 4~300 | 4~300 | 25~300 | 25~300 | 35~300 | - | |
4 | 4~240 | 4~240 | - | - |
|
|
Oil resistant cable: used for numericalcontrol machine tool equipment electrical connection
Waterproof cable: used foroutdoor, underground pipelines, CMC channel and humidity larger environment
Rattermite cable: used for important signal transmission cable, power cable, caneffectively prevent the rats, ants and insects chewing on cable
Resistance to low temperaturecable: used for outdoor, cold storage equipment working environment, theminimum resistance low temperature - degrees, in low temperature environmentcable can still keep soft condition, no crack, convenient operation.
Environmental protectioncable: the environmental protection plastics, widely used in environmentalprotection requirements of strict place.
Flame retardant cable: theflame retardant plastic, in case of fire can effectively prevent fire spreadalong the wire.
Integrated cable: accordingto the customer request or sample production lines, the various equipment line,line integrated in a piece of wire inside, plus sheath of protection wiringbeautiful and extend cable service life. According to the different useenvironment can choose oil resistant sheath, waterproof jacket, resistance tolow temperature sheath, ring protective sleeve, general PVC sheathed, elasticsheath, flame retardant sheath and so on many kinds of types for wiringoperation to provide adequate agility and convenience
Our company production and operation 3.6/6 kv -26/35 kv crosslinking of polyvinyl chloride (PVC) power cable, 0.6/1 kvcrosslinking of polyvinyl chloride (PVC) power cable, plastic insulationcontrol cable, 10 kv / 35 kv overhead insulated cable, PVC insulated wire, lowsmoke zero halogen, flame retardant, refractory, power cable, mine rubbersleeve soft cable, general rubber sleeve soft cable, computer cable, signalcable, coaxial cable, waterproof cable, communication cable, insulatedconductor.
insulated conductor:BV BVR RV BLV
Flame retardantfire-resistant wire:ZRBV ZABV ZBBV ZCBV ZDBV ZRBVR ZRRV
Sheath line:RVV RVVP
Cross-linking power cable:VV、VV22、YJV、YJV22、VLV.VLV22、YJLV、YJLV22
Flame retardant power cable:ZRVV、ZRVV22、ZRYJV、ZRYJV22、ZRYJLV、ZRYJLV22
Refractory power cable:NHVV、NHVV22、NHYJV、NHYJV22
The low smoke, zero halogenseries:WDZB-YJY、WDZB-YJY22、WDZB-VV、WDZB-VV22、WDZB-YJLY、WDZB-YJLY22
cabtyre cable:YZ YC YH YCW YZW YQ YQW
Flame retardant rubber sleevecable:ZC-YZ、ZC-YC、ZC-YH、ZC-YZ、ZA-YC、ZA-YH、ZA-YZW、ZC-YCW、ZC-YZW
Screened control panel cable:KVV KVV22 KVVP KVVP22 KVVP2 KVVP2-22 KVVR KVVRP
computer cable:
DJYPV/DJYP2V/DJYP3V/DJYVP/DJYVP2/DJYVP3/DJYPVP/DJYP2VP2 DJYP3VP3/DJYPVR/DJYP2VR/DJYP3VR/DJYVPR/DJYVP2R/DJYVP3R/DJYPVPR DJYP2VP2R/DJYP3VP3R/DJYPV22/DJYP2V22/DJYP3V22/DJYVP22/DJYVP2-22 DJYVP3-22/DJYPVP22/DJYP2VP2-22/DJYP3VP3-22
communication cable:HYA HYV HYAV HYAC HYAT CPEV CPEV-S
Shielding communication cable:HYVP HYAP MHYVP MHYVP MHYVRP RVSP
Armore communication cable:
HYA53 MHYA32 MHYV22 MHYAV22 MHYAV32 HYAT53 HYV22 HYV32 HYA32 HYV53 HYVP22 HYAP22 HYAP32 MHYVP22 MHYVP32 MHYVRP22 MHYVRP32
Flame retardant communicationcable:ZR-HYA ZRA-HYA ZA-HYA ZRC-HYA WDZ-HYA ZR-YJYR